FZN25 Indoor Vacuum Load Break Switch
Product Overview
- Material: Copper with Silver Glavizanition
- Rated Voltage: 12kV, 15kV
- Rated Current: 630A
- Standards: IEC 62271-102
- Use for Air Switchgear, Ring Main Units
- Arc-extinguish: Vacuum Interrupter
FZN25 Indoor Vacuum Load Break Switch
General
FZN25-12D/T630-20 Indoor AC medium voltage vacuum load break switch is three-phase AC 50/60 Hz, rated voltage 12kV indoor installation, which is suitable for using in industrial and mining situation and so on enterprise substation and transformer and cable charging current. It had manual and motor operating mechanism that is advantageous to realize remote control. FZRN25-12D/T[]-31.5 indoor AC medium voltage vacuum load break switch with fuse combination, The versions combined with HRC fuses are particularly suitable for the protection of distribution transformers up to 1250 kVA, to break fault current and over load current.
General
FZN25-12D/T630-20 Indoor AC medium voltage vacuum load break switch is three-phase AC 50/60 Hz, rated voltage 12kV indoor installation, which is suitable for using in industrial and mining situation and so on enterprise substation and transformer and cable charging current. It had manual and motor operating mechanism that is advantageous to realize remote control. FZRN25-12D/T[]-31.5 indoor AC medium voltage vacuum load break switch with fuse combination, The versions combined with HRC fuses are particularly suitable for the protection of distribution transformers up to 1250 kVA, to break fault current and over load current.
Technical Data
Technical specification FZN25 | |||||
Rated Voltage | kV | 12 | |||
Rated Current | A | 630 | |||
Rated Power Frequency | Hz | 50/60 | |||
Short Circuit Making Capacity | kApeak | 50 | |||
Peak Withstand Current | kApeak | 50 | |||
Short Time Current -1sec. -3sec. |
A A |
25 20 |
|||
Max. Breaking Capacity in Co-operation with Fuses (test duty 4, IEC 62271-105) | A | 2000 | |||
Max. fuse current(XRNT Fuse) | A | 200 | |||
Power frequency withstand voltage 50Hz 1 min. | |||||
– To earth and between poles | kV | 42 | |||
-Across isolating distance | kV | 48 | |||
Impulse Withstand voltage 1.2/50μs | |||||
– To earth and between poles | kV | 75 | |||
-Across isolating distance | kV | 85 | |||
Mechanism Endurance | |||||
– Vacuum Interrupter | cycles | 10,000 | |||
– Main Switch and Earth Switch | cycles | 2,000 |
Drawings
Packing Details
Model | Description | Gross Weight/kgs | Net Weight/kgs | Volumn/m3 | Packing Size/m |
FZN-12DR | 12kV VLBS with fuse holder and earth switch | 0.46 | 1.04×0.90×0.49 | ||